Offshore steel structures and ship coating (heavy-duty)
Model

SeaForce 90 acrylic

SeaForce 90 is a acrylic primer / intermediate coat / topcoat / antifouling from the Jotun range, formulated for steel structures in immersion service / low-temperature application. For the complete technical data, request the manufacturer's TDS and SDS for SeaForce 90.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

SeaForce 90 — product overview

This is a one-component acrylic product, typically used as primer / intermediate coat / topcoat / antifouling. It is characterised by manufactured to the manufacturer's technical data sheet; service environment immersion service / low-temperature application; suitable for protective coating of carbon steel.

SeaForce 90 — positioning

SeaForce 90 belongs to the acrylic family of Jotun protective coatings and is used as primer / intermediate coat / topcoat / antifouling in immersion service / low-temperature application service.

Three things decide the system: the substrate (carbon steel), the service environment (immersion service / low-temperature application) and the design life. Together they set the number of coats and the total film thickness.

Manufactured to the manufacturer's technical data sheet; the service data on this page follow it.

Typical service environment: immersion service / low-temperature application.

SeaForce 90 — key data

ModelSeaForce 90
Manufacturer product name0TX
Resin systemacrylic
Componentsone-component
Typical number of coatsprimer / intermediate coat / topcoat / antifouling
Service environmentimmersion service / low-temperature application
Suitable substratescarbon steel
Colour rangeStandard: dark red / light red
Application methodairless spray / brush / roller
Volume solids58 % ± 2 %
Density (specific gravity)1.7 kg/l
Flash point28 °C
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-seaforce-90.pdf)

Application and system notes

Application: airless spray / brush / roller. Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature-10 °C0 °C5 °C10 °C23 °C40 °C
Touch dry5 h2 h1 h45 min30 min30 min
Recoat, minimum48 h36 h12 h9 h7 h6 h

Data taken from the manufacturer's TDS jotun-seaforce-90.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Coat sequence, film thickness and quantity depend on the service conditions (carbon steel / immersion service / low-temperature application) and the design life: give us the structure type, corrosivity category and area, and the quantity can be calculated.

Standards and approvals

Standard numbers are given for selection checks; valid, in-date documents for formal tenders or acceptance are supplied per model.

SeaForce 90 — requesting technical data

Volume solids, recommended dry film thickness, theoretical spreading rate, drying and curing times and VOC are itemised in the manufacturer's technical data sheet (TDS).

For the full technical data on SeaForce 90, use the WhatsApp or email link at the foot of this page; the TDS and SDS are sent together.

SeaForce 90 — common questions

What are the key characteristics of SeaForce 90?

This model offers manufactured to the manufacturer's technical data sheet. Suitability for a particular service condition still has to be assessed together with the complete coating system.

How is the recoat interval for SeaForce 90 controlled?

The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.

Which substrates can SeaForce 90 be used on?

The TDS lists the substrate as carbon steel; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.

Models related to SeaForce 90

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for SeaForce 90

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code
Scan to add us on WeChat