Offshore steel structures and ship coating (heavy-duty)
Model

Tankguard Storage HS phenolic epoxy

Tankguard Storage HS (6R6) — in the Jotun range — is a phenolic epoxy product normally used as primer / intermediate coat / topcoat where atmospheric exposure / immersion service conditions apply. This model offers chemical-resistant. For the complete technical data, request the manufacturer's TDS and SDS for Tankguard Storage HS.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

Tankguard Storage HS — product overview

two-component phenolic epoxy product for use as primer / intermediate coat / topcoat; chemical-resistant; substrates carbon steel / galvanised steel / stainless steel / concrete; service environment atmospheric exposure / immersion service.

Tankguard Storage HS — positioning

Jotun's Tankguard Storage HS is a phenolic epoxy primer / intermediate coat / topcoat for atmospheric exposure / immersion service conditions, supplied with its technical documentation.

Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.

The model is notable for chemical-resistant.

It is used for protective coating work in atmospheric exposure / immersion service conditions.

Tankguard Storage HS — key data

ModelTankguard Storage HS
Manufacturer product name6R6
Resin systemphenolic epoxy
Componentstwo-component
Typical number of coatsprimer / intermediate coat / topcoat
Service environmentatmospheric exposure / immersion service
Suitable substratescarbon steel / galvanised steel / stainless steel / concrete
Key characteristicschemical-resistant
Colour rangeLight grey / light red
Application methodairless spray / brush / roller
Surface preparation gradesa 2½
Volume solids72 % ± 2 %
Density (specific gravity)1.5 kg/l
Flash point34 °C
GlossSemi-gloss (35-70)
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-tankguard-storage-hs.pdf)

Application and system notes

Application: airless spray / brush / roller (sa 2½). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature-5 °C0 °C5 °C10 °C15 °C23 °C40 °C
Touch dry12 h10 h5 h4 h3 h2 h1 h
Walk-on dry48 h30 h16 h12 h10 h8 h4 h
Recoat, minimum24 h20 h10 h8 h6 h4 h2 h
Dried/cured for service30 d21 d14 d10 d8 d6 d3 d

Data taken from the manufacturer's TDS jotun-tankguard-storage-hs.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Within a system, the coat sequence and film thickness depend on the substrate (carbon steel / galvanised steel / stainless steel / concrete), the corrosivity category and the design life; send the project conditions and we can recommend both sequence and quantity.

Standards and approvals

The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.

Tankguard Storage HS — requesting technical data

Volume solids, single-coat dry film thickness, recoat interval, drying time and VOC are as stated in the manufacturer's TDS.

To get the manufacturer TDS and SDS for Tankguard Storage HS, send a request at the foot of this page, or contact us on WhatsApp or by email.

Tankguard Storage HS — common questions

Which coat does Tankguard Storage HS take in the system?

This model is typically used as primer / intermediate coat / topcoat. The number of coats and film thickness depend on the substrate, the corrosivity category and the design life.

What are the minimum order quantity and lead time for Tankguard Storage HS?

Supply is in full drums or full pallets, with staged deliveries to match the application programme. Coatings are flammable dangerous goods carried by licensed carriers; lead time is confirmed by model and quantity.

What are the key characteristics of Tankguard Storage HS?

This model offers chemical-resistant. Suitability for a particular service condition still has to be assessed together with the complete coating system.

Models related to Tankguard Storage HS

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for Tankguard Storage HS

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code
Scan to add us on WeChat