Pioner Topcoat acrylic
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Pioner Topcoat — product overview
Pioner Topcoat belongs to the acrylic system and is a one-component product used as topcoat; service environment atmospheric exposure; application and system notes are set out below.
Pioner Topcoat — positioning
Jotun's Pioner Topcoat is a acrylic topcoat for atmospheric exposure conditions, supplied with its technical documentation.
Three things decide the system: the substrate (steel), the service environment (atmospheric exposure) and the design life. Together they set the number of coats and the total film thickness.
Manufactured to the manufacturer's technical data sheet; the service data on this page follow it.
Typical service environment: atmospheric exposure.
Pioner Topcoat — key data
| Model | Pioner Topcoat |
|---|---|
| Manufacturer product name | 0FV |
| Resin system | acrylic |
| Components | one-component |
| Typical number of coats | topcoat |
| Service environment | atmospheric exposure |
| Colour range | A range of colours (colour card on request) |
| Application method | airless spray / brush / roller |
| Volume solids | 34 % ± 2 % |
| Density (specific gravity) | 1.1 kg/l |
| Flash point | 37 °C |
| Gloss | Semi-gloss (35-70) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-pioner-topcoat.pdf) |
Application and system notes
Application: airless spray / brush / roller. Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|
| Touch dry | 1 h | 45 min | 30 min | 15 min |
| Walk-on dry | 10 h | 9 h | 7 h | 4 h |
| Recoat, minimum | 5 h | 4 h | 2 h | 1.5 h |
Data taken from the manufacturer's TDS jotun-pioner-topcoat.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Within a system, the coat sequence and film thickness depend on the substrate (steel), the corrosivity category and the design life; send the project conditions and we can recommend both sequence and quantity.
Standards and approvals
- IMO 2010 FTP
- ISO 2813
- ISO 3233
- ISO 3679
The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.
Pioner Topcoat — requesting technical data
Quotations and application plans rest on film thickness, spreading rate and curing time — all taken from the original TDS.
To get the manufacturer TDS and SDS for Pioner Topcoat, send a request at the foot of this page, or contact us on WhatsApp or by email.
Pioner Topcoat — common questions
How is the recoat interval for Pioner Topcoat controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Pioner Topcoat be used on?
The TDS lists the substrate as steel; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
What service environment suits Pioner Topcoat?
The service environment for this model is atmospheric exposure. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.
Models related to Pioner Topcoat
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Pioner Topcoat
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat