Offshore steel structures and ship coating (heavy-duty)
Model

Conseal Touch-Up acrylic

A acrylic topcoat in the Jotun range, Conseal Touch-Up () is selected for steel structures exposed to atmospheric exposure / low-temperature application. This model offers high-build. For the complete technical data, request the manufacturer's TDS and SDS for Conseal Touch-Up.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

Conseal Touch-Up — product overview

one-component acrylic product for use as topcoat; high-build; substrates steel; service environment atmospheric exposure / low-temperature application.

Conseal Touch-Up — positioning

Conseal Touch-Up () is the acrylic topcoat in the Jotun range; this page sets out its system position, parameters and supply.

Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.

Where high-build are specified, it combines with other products of the same system into a complete scheme.

It is used for protective coating work in atmospheric exposure / low-temperature application conditions.

Conseal Touch-Up — key data

ModelConseal Touch-Up
Manufacturer product name
Resin systemacrylic
Componentsone-component
Typical number of coatstopcoat
Service environmentatmospheric exposure / low-temperature application
Key characteristicshigh-build
Colour rangeA range of colours (colour card on request)
Application methodairless spray / brush / roller
Surface preparation gradesa 2½ / sa 2 / st 2
Volume solids49 % ± 2 %
Density (specific gravity)1.2 kg/l
Flash point25 °C
GlossMatt (0-35)
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-conseal-touch-up.pdf)

Application and system notes

Application: airless spray / brush / roller (sa 2½ / sa 2 / st 2). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature-5 °C0 °C5 °C10 °C23 °C40 °C
Touch dry30 min20 min17 min15 min10 min10 min
Walk-on dry20 h20 h17 h11 h10 h6 h
Recoat, minimum4 h4 h3 h2.5 h2 h1.5 h

Data taken from the manufacturer's TDS jotun-conseal-touch-up.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Within a system, the coat sequence and film thickness depend on the substrate (steel), the corrosivity category and the design life; send the project conditions and we can recommend both sequence and quantity.

Standards and approvals

The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.

Conseal Touch-Up — requesting technical data

Volume solids, recommended dry film thickness, theoretical spreading rate, drying and curing times and VOC are itemised in the manufacturer's technical data sheet (TDS).

Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Conseal Touch-Up and the intended use.

Conseal Touch-Up — common questions

How is the recoat interval for Conseal Touch-Up controlled?

The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.

Which substrates can Conseal Touch-Up be used on?

The TDS lists the substrate as steel; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.

What service environment suits Conseal Touch-Up?

The service environment for this model is atmospheric exposure / low-temperature application. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.

Models related to Conseal Touch-Up

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for Conseal Touch-Up

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code
Scan to add us on WeChat