Offshore steel structures and ship coating (heavy-duty)
Model

Penguard Clear Sealer epoxy

A epoxy primer / topcoat in the Jotun range, Penguard Clear Sealer (1BA) is selected for steel structures exposed to atmospheric exposure. For the complete technical data, request the manufacturer's TDS and SDS for Penguard Clear Sealer.

China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.

This model belongs to the categories below; select a tag to see every model in that category.

Penguard Clear Sealer — product overview

Penguard Clear Sealer belongs to the epoxy system and is a two-component product used as primer / topcoat; service environment atmospheric exposure; application and system notes are set out below.

Penguard Clear Sealer — positioning

Penguard Clear Sealer belongs to the epoxy family of Jotun protective coatings and is used as primer / topcoat in atmospheric exposure service.

The substrate for this product is concrete. Prepare the surface as the manufacturer requires, and check ambient temperature, humidity and dew point before starting.

This model is manufactured to the manufacturer's technical data sheet.

It is used for protective coating work in atmospheric exposure conditions.

Penguard Clear Sealer — key data

ModelPenguard Clear Sealer
Manufacturer product name1BA
Resin systemepoxy
Componentstwo-component
Typical number of coatsprimer / topcoat
Service environmentatmospheric exposure
Suitable substratesconcrete
Colour rangeClear
Application methodairless spray / brush / roller
Volume solids44 % ± 2 %
Density (specific gravity)0.97 kg/l
Flash point25 °C
GlossGloss (70-85)
Packaging and deliverySupplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model
SourceManufacturer technical data sheet (jotun-penguard-clear-sealer.pdf)

Application and system notes

Application: airless spray / brush / roller. Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.

Drying and curing times

Substrate temperature10 °C23 °C40 °C
Touch dry2 h1 h30 min
Walk-on dry14 h6.5 h4 h
Recoat, minimum8 h4 h2 h
Dried/cured for service14 d7 d3 d

Data taken from the manufacturer's TDS jotun-penguard-clear-sealer.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.

Coat sequence, film thickness and quantity depend on the service conditions (concrete / atmospheric exposure) and the design life: give us the structure type, corrosivity category and area, and the quantity can be calculated.

Standards and approvals

The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.

Penguard Clear Sealer — requesting technical data

Quotations and application plans rest on film thickness, spreading rate and curing time — all taken from the original TDS.

For the full technical data on Penguard Clear Sealer, use the WhatsApp or email link at the foot of this page; the TDS and SDS are sent together.

Penguard Clear Sealer — common questions

How is the recoat interval for Penguard Clear Sealer controlled?

The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.

Which substrates can Penguard Clear Sealer be used on?

The TDS lists the substrate as concrete; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.

What service environment suits Penguard Clear Sealer?

The service environment for this model is atmospheric exposure. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.

Models related to Penguard Clear Sealer

Back to Products to filter every model by use or type

Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.

Sales & technical support

Detailed data and a quotation for Penguard Clear Sealer

We supply Jotun industrial coatings made in China and handle the export. Get in touch.

WeChat QR code
Scan to add us on WeChat