Hardtop AX K II polyurethane
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Hardtop AX K II — product overview
This is a two-component polyurethane product, typically used as topcoat. It is characterised by chemical-resistant; service environment atmospheric exposure; suitable for protective coating of steel.
Hardtop AX K II — positioning
Hardtop AX K II is the polyurethane topcoat in Jotun's protective coatings line, specified for atmospheric exposure service.
Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.
Where chemical-resistant are specified, it combines with other products of the same system into a complete scheme.
Typical service environment: atmospheric exposure.
Hardtop AX K II — key data
| Model | Hardtop AX K II |
|---|---|
| Manufacturer product name | 0XH |
| Resin system | polyurethane |
| Components | two-component |
| Typical number of coats | topcoat |
| Service environment | atmospheric exposure |
| Key characteristics | chemical-resistant |
| Colour range | A range of colours (colour card on request) |
| Application method | airless spray / brush / roller |
| Volume solids | 64 % ± 2 % |
| Density (specific gravity) | 1.4 kg/l |
| Flash point | 27 °C |
| Gloss | Gloss (70-85) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-hardtop-ax-k-ii.pdf) |
Application and system notes
Application: airless spray / brush / roller. Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | -5 °C | 0 °C | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|---|---|
| Touch dry | 12 h | 10 h | 8 h | 4 h | 2 h | 1 h |
| Recoat, minimum | 54 h | 24 h | 18 h | 14 h | 6 h | 3 h |
| Dried/cured for service | 30 d | 20 d | 14 d | 10 d | 7 d | 3 d |
Data taken from the manufacturer's TDS jotun-hardtop-ax-k-ii.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Coat sequence, film thickness and quantity depend on the service conditions (steel / atmospheric exposure) and the design life: give us the structure type, corrosivity category and area, and the quantity can be calculated.
Standards and approvals
- ISO 2813
- ISO 3233
- ISO 3679
The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.
Hardtop AX K II — requesting technical data
Quotations and application plans rest on film thickness, spreading rate and curing time — all taken from the original TDS.
For the full technical data on Hardtop AX K II, use the WhatsApp or email link at the foot of this page; the TDS and SDS are sent together.
Hardtop AX K II — common questions
How is the recoat interval for Hardtop AX K II controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Which substrates can Hardtop AX K II be used on?
The TDS lists the substrate as steel; surface preparation must be completed and cleanliness and roughness confirmed, and ambient temperature, humidity and dew point must be within limits before coating.
What service environment suits Hardtop AX K II?
The service environment for this model is atmospheric exposure. The corrosivity category determines the coat sequence and film thickness; send the project conditions and the specific build-up can be given.
Models related to Hardtop AX K II
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Hardtop AX K II
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat
- Email max@rich-tech.net