Penguard Shield GF epoxy
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Penguard Shield GF — product overview
two-component epoxy product for use as primer / intermediate coat / topcoat; fast-drying / abrasion-resistant; substrates carbon steel / stainless steel / concrete / coated surfaces; service environment atmospheric exposure / immersion service / low-temperature application.
Penguard Shield GF — positioning
Penguard Shield GF is a epoxy primer / intermediate coat / topcoat from the Jotun range, formulated for steel structures in atmospheric exposure / immersion service / low-temperature application.
Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.
The model is notable for fast-drying / abrasion-resistant.
Service environments include atmospheric exposure / immersion service / low-temperature application; send the actual conditions for anything outside that range.
Penguard Shield GF — key data
| Model | Penguard Shield GF |
|---|---|
| Manufacturer product name | 6Q7 |
| Resin system | epoxy |
| Components | two-component |
| Typical number of coats | primer / intermediate coat / topcoat |
| Service environment | atmospheric exposure / immersion service / low-temperature application |
| Suitable substrates | carbon steel / stainless steel / concrete / coated surfaces |
| Key characteristics | fast-drying / abrasion-resistant |
| Colour range | Light grey / Red / Light yellow / White / Black |
| Application method | airless spray / brush / roller |
| Surface preparation grade | sa 2½ / sa 2 / st 2 |
| Volume solids | 72 % ± 2 % |
| Density (specific gravity) | 1.4 kg/l |
| Flash point | 30 °C |
| Gloss | Matt (0-35) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-penguard-shield-gf.pdf) |
Application and system notes
Application: airless spray / brush / roller (sa 2½ / sa 2 / st 2). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | -5 °C | 0 °C | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|---|---|
| Touch dry | 15 h | 11 h | 7 h | 5 h | 2 h | 1 h |
| Walk-on dry | 35 h | 24 h | 14 h | 10 h | 5 h | 2 h |
| Recoat, minimum | 25 h | 16 h | 10 h | 7 h | 4 h | 2 h |
| Dried/cured for service | 28 d | 21 d | 14 d | 11 d | 7 d | 4 d |
Data taken from the manufacturer's TDS jotun-penguard-shield-gf.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Usually applied as primer / intermediate coat / topcoat; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / stainless steel / concrete / coated surfaces and the corrosivity of the atmospheric exposure / immersion service / low-temperature application environment.
Standards and approvals
- GB 30981.2
- GB 30981.2-2025
- ISO 2813
- ISO 3233
- ISO 3679
- ISO 8501-1
- ISO 8501-2
Standards and approvals for Penguard Shield GF follow the manufacturer's current technical data sheet; tell us the purpose and the recipient if you need scanned certificates.
Penguard Shield GF — requesting technical data
Quotations and application plans rest on film thickness, spreading rate and curing time — all taken from the original TDS.
Full documentation — TDS, SDS, test and certification documents — is available on request: quote the model Penguard Shield GF and the intended use.
Penguard Shield GF — common questions
How many components does Penguard Shield GF have, and how is it mixed?
This model is a two-component product. Mixing ratio, pot life and induction time follow the manufacturer's TDS; deviation from the ratio affects curing and adhesion.
Where can I find the technical data for Penguard Shield GF?
Volume solids, film thickness, spreading rate, drying time and VOC are as stated in the manufacturer's TDS; the current version for this model is available from us.
Which coat does Penguard Shield GF take in the system?
This model is typically used as primer / intermediate coat / topcoat. The number of coats and film thickness depend on the substrate, the corrosivity category and the design life.
Models related to Penguard Shield GF
- Jotacote HF002
- Jotacote Universal
- Jotacote Universal HF002
- Penguard EXA II
- Penguard Universal
- Jotacote B10
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Penguard Shield GF
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat
- Email max@rich-tech.net