Penguard HSP E epoxy
China-based distributor of Jotun industrial protective coatings — supplied from the China production base to projects worldwide.
This model belongs to the categories below; select a tag to see every model in that category.
Penguard HSP E — product overview
two-component epoxy product for use as primer / intermediate coat; fast-drying / high solids / high-build; substrates carbon steel / galvanised steel / stainless steel; service environment atmospheric exposure.
Penguard HSP E — positioning
Penguard HSP E (0N3) is the epoxy primer / intermediate coat in the Jotun range; this page sets out its system position, parameters and supply.
Within a coating system it can take the appropriate coat for steelwork, tanks and pipelines; the coat sequence and thickness follow the manufacturer's recommended scheme.
The model is notable for fast-drying / high solids / high-build.
Typical service environment: atmospheric exposure.
Penguard HSP E — key data
| Model | Penguard HSP E |
|---|---|
| Manufacturer product name | 0N3 |
| Resin system | epoxy |
| Components | two-component |
| Typical number of coats | primer / intermediate coat |
| Service environment | atmospheric exposure |
| Suitable substrates | carbon steel / galvanised steel / stainless steel |
| Key characteristics | fast-drying / high solids / high-build |
| Colour range | A range of colours (colour card on request) |
| Application method | airless spray / brush |
| Surface preparation grade | sa 2½ / sa 2 / st 2 |
| Volume solids | 75 % ± 2 % |
| Density (specific gravity) | 1.64 kg/l |
| Flash point | 27 °C |
| Gloss | Matt (0-35) |
| Packaging and delivery | Supplied in full drums or full pallets, with staged deliveries to match the progress on site; pack sizes are confirmed per model |
| Source | Manufacturer technical data sheet (jotun-penguard-hsp-e.pdf) |
Application and system notes
Application: airless spray / brush (sa 2½ / sa 2 / st 2). Before application, confirm the surface preparation grade and control ambient temperature and humidity, substrate temperature and dew point as the manufacturer requires; observe the specified recoat intervals.
Drying and curing times
| Substrate temperature | 0 °C | 5 °C | 10 °C | 23 °C | 40 °C |
|---|---|---|---|---|---|
| Touch dry | 11 h | 5 h | 2 h | 1 h | 30 min |
| Walk-on dry | 18 h | 12 h | 6 h | 3 h | 2 h |
| Recoat, minimum | 18 h | 12 h | 4 h | 2 h | 1 h |
| Dried/cured for service | 21 d | 13 d | 8 d | 4 d | 3 d |
Data taken from the manufacturer's TDS jotun-penguard-hsp-e.pdf (page 4); 23 °C is the reference condition, the other columns are given for application in different seasons and regions. The full data sheet is available from us on request.
Usually applied as primer / intermediate coat; the number of coats and the quantity per unit depend on the surface condition of the carbon steel / galvanised steel / stainless steel and the corrosivity of the atmospheric exposure environment.
Standards and approvals
- GB 38508-2020
- ISO 2813
- ISO 3233
- ISO 3679
- ISO 8501-1
The standard numbers above come from the manufacturer's technical data sheet; original certificates and their conditions of validity can be supplied, or checked against the manufacturer's documents.
Penguard HSP E — requesting technical data
Volume solids, single-coat dry film thickness, recoat interval, drying time and VOC are as stated in the manufacturer's TDS.
To get the manufacturer TDS and SDS for Penguard HSP E, send a request at the foot of this page, or contact us on WhatsApp or by email.
Penguard HSP E — common questions
What are the minimum order quantity and lead time for Penguard HSP E?
Supply is in full drums or full pallets, with staged deliveries to match the application programme. Coatings are flammable dangerous goods carried by licensed carriers; lead time is confirmed by model and quantity.
What are the key characteristics of Penguard HSP E?
This model offers fast-drying / high solids / high-build. Suitability for a particular service condition still has to be assessed together with the complete coating system.
How is the recoat interval for Penguard HSP E controlled?
The minimum and maximum recoat intervals follow the manufacturer's TDS and must also satisfy the on-site temperature, humidity and dew point conditions.
Models related to Penguard HSP E
Back to Products to filter every model by use or type
Model and category information on this page is compiled from the manufacturer's technical data sheets and is provided for selection reference; parameters, application requirements and suitability are governed by the manufacturer's latest technical data sheet and by the actual site conditions. This site does not replace the manufacturer's documents.
Sales & technical support
Detailed data and a quotation for Penguard HSP E
We supply Jotun industrial coatings made in China and handle the export. Get in touch.
- WhatsApp Start a chat
- Email max@rich-tech.net